Rinnai tankless water heater error codes

45 codes with causes and test steps, plus 13 settings tables.

CodeMeaningSeverity
02Burner did not operate during freeze protectionHigh
03Power interrupted during bath fillLow
05Bypass flow control device faultMedium
07Circulation flow rate below 2.1 GPMMedium
10Air supply or exhaust blocked / condensate trap fullCritical
11No ignitionHigh
12Flame failureHigh
13Combustion faultCritical
14Thermal fuse or overheat sensor trippedCritical
15Venturi control faultHigh
16Outlet water over-temperature safety shutdownCritical
17Venturi blockageHigh
18Gas valve air/fuel adjustment limit reachedHigh
19Electrical grounding / DC circuit shortHigh
21PC board data transfer errorHigh
22Gas valve adjustment faultMedium
25Condensate pump failure or clogged drainMedium
30Flammable vapor sensor activated or faultyCritical
31Burner thermocouple out of rangeHigh
32Outlet water temperature thermistor faultMedium
33Heat exchanger thermistor faultMedium
34Combustion air thermistor (Non-SENSEI) / Lime detecting thermistor (RX/CX)Medium
35Tank temperature sensor faultMedium
38Exhaust gas temperature sensor (CO sensor on RH180)Critical
41Freeze protection / outdoor air temperature sensor faultMedium
51Inlet water temperature thermistor faultMedium
52Gas valve / modulating solenoid valve (POV) signal faultHigh
54High exhaust gas temperatureCritical
57Burner overheat bi-metal switch openCritical
58Secondary heat exchanger bi-metal switch openHigh
61Combustion fan motor faultHigh
63Recirculation low flowMedium
65Water flow control device (servo) faultMedium
66Bypass flow servo faultMedium
70PC board faultHigh
71Gas solenoid valve fault (SV0–SV4 on Non-SENSEI)High
72Flame rod faultHigh
73Burner thermocouple faultHigh
79Water leakage detectedHigh
FEFlammable vapors detectedCritical
FFMaintenance performed (history marker)Low
LCScale build-up in heat exchanger (LC, LC0–LC9, 00)Medium
SECascade diagnostic display (error on secondary unit)Medium
SEtInitial settings not yet confirmedLow
SSService Soon alert (also listed as 55)Low

Settings and specs

RSC supply connection sizes

Specifications · SENSEI

ConnectionSize
Gas3/4 in. NPT
Cold inlet3/4 in. NPT
Hot outlet3/4 in. NPT
Condensate drain1/2 in. NPT
Pressure relief valveM33 thread
  • The PRV and its adapter come in the box; PRV must be rated 150 psi and at least the heater Btu/h.
  • Condensate drain line must stay at least 1/2 in. over its whole length.

Source: Rinnai RSC SENSEI Installation and Operation Manual (100000773), Table 3 Supply Connections, p.14

RSC water quality limits

Water quality · SENSEI

ContaminantMaximum level
Total hardnessUp to 200 mg/L
AluminumUp to 0.2 mg/L
ChloridesUp to 250 mg/L
CopperUp to 1.0 mg/L
Dissolved CO2Up to 15.0 mg/L
IronUp to 0.3 mg/L
ManganeseUp to 0.05 mg/L
pH6.5 to 8.5
TDSUp to 500 mg/L
ZincUp to 5 mg/L
  • Damage from water above these limits is not covered by warranty.
  • Hard water should be treated; use the Service Soon (SS) reminder (parameter 03) for flushing intervals.

Source: Rinnai RSC SENSEI Installation and Operation Manual (100000773), Table 5 Water Quality Guidelines, p.19

RSC clearances to combustibles

Clearances · SENSEI

LocationClearance
Top2 in. (51 mm); 0 in. from vent components
Bottom/ground12 in. (305 mm)
Front0 in.; 24 in. (610 mm) service clearance
Back0 in.
Sides2 in. (51 mm); add 0.25 in. (6.35 mm) for recess box
Vent0 in.
Front exhaust (outdoor models)24 in. (610 mm)
  • Same values apply to combustible and non-combustible surfaces.

Source: Rinnai RSC SENSEI Installation and Operation Manual (100000773), Table 6 Clearances, p.22

RSC temperature settings available

Installer menu / Control settings · SENSEI

FCNote
9837-
10038-
10239-
10440Default after power loss if unit was powered under 6 h
10641-
10842-
11043Highest setting while hot water is flowing
11546-
12049Default max; crossover mode minimum
12552Needs parameter 01b
13054Needs parameter 01b
13557Needs parameter 01b
14060Needs parameter 01b
  • While hot water is running the setting can only be changed between 98 F and 110 F.
  • Switch F/C: hold On/Off 5 s with the heater off.
  • Above 125 F (52 C) water can scald; check local code limits for public buildings.

Source: Rinnai RSC SENSEI Installation and Operation Manual (100000773), Table 32, p.69-70

RX supply connection sizes

Specifications · SENSEI RX/CX

ConnectionSize
Gas3/4 in. MNPT
Cold inlet3/4 in. MNPT
Hot outlet3/4 in. MNPT
Condensate drain1/2 in. MNPT
  • Vent connection: 2 in. nominal PVC/CPVC/PP or 3 in./5 in. concentric.
  • Full specs (input, flow, weight) are only on each model's spec sheet, not in this manual.
  • Supplied power cord is 6.5 ft (2.0 m), outdoor rated; 120 VAC 60 Hz grounded.

Source: Rinnai SENSEI RX Residential Installation and Operation Manual (100000839(03)), Table 2 Supply Connections, p.8; power p.45

RX water quality limits

Water quality · SENSEI RX/CX

ContaminantMaximum level
Total hardnessUp to 200 mg/L
AluminumUp to 0.2 mg/L
ChloridesUp to 250 mg/L
CopperUp to 1.0 mg/L
Dissolved CO2Up to 15.0 mg/L
IronUp to 0.3 mg/L
ManganeseUp to 0.05 mg/L
pH6.5 to 8.5
TDSUp to 500 mg/L
ZincUp to 5 mg/L
  • Water damage beyond these limits is not covered by warranty.

Source: Rinnai SENSEI RX Residential Installation and Operation Manual (100000839(03)), Table 4 Water Quality Guidelines, p.11

RX water treatment and flushing by hardness

Water quality · SENSEI RX/CX

ClassHardness mg/LGrains/galTreatmentFlushing
Soft0-600-4NoneNone
Slightly hard61-1204-7Softener or Rinnai Scale Cutter recommendedResidential once/year; commercial twice/year
Moderately hard121-1607-9Softener or Rinnai Scale Cutter recommendedResidential once/year; commercial twice/year
Very hard161-2009-12Softener or Rinnai Scale Cutter strongly recommendedResidential once/year; commercial twice/year
Extremely hard200+12+Softener or Rinnai Scale Cutter requiredResidential once/year; commercial twice/year
  • Use parameter 03 (Service Soon) to remind the owner to flush.

Source: Rinnai SENSEI RX Residential Installation and Operation Manual (100000839(03)), Table 3 Recommended Water Treatment, p.11

RX clearances to combustibles

Clearances · SENSEI RX/CX

LocationClearance
Top2 in. (51 mm); 0 in. from vent components
Bottom/ground12 in. (305 mm)
Front0 in.; 24 in. (610 mm) service clearance
Back0 in.
Sides2 in. (51 mm); add 0.25 in. (6.35 mm) for recess box
Vent0 in.
  • Same values for combustible and non-combustible surfaces.
  • Freeze protection down to -22 F (-30 C) indoors and -4 F (-20 C) outdoors with power on and no direct wind (p.12).

Source: Rinnai SENSEI RX Residential Installation and Operation Manual (100000839(03)), Table 5 Clearances, p.13

RX temperature settings available

Installer menu / Control settings · SENSEI RX/CX

FCNote
9837-
10038-
10239-
10440Default after power loss if unit was powered under 6 h
10641-
10842-
11043Highest setting while hot water is flowing
11546-
12049Default max; crossover mode minimum
12552Needs parameter 01b
13054Needs parameter 01b
13557Needs parameter 01b
14060Needs parameter 01b
  • While hot water is running the setting can only be changed between 98 F and 110 F (37-43 C).
  • Switch F/C: hold On/Off 5 s with the heater off. Outdoor units auto-lock the controller after 30 min idle.

Source: Rinnai SENSEI RX Residential Installation and Operation Manual (100000839(03)), Table 29 Temperature Settings, p.57-58

RUCS/RUS unit clearances

Clearances · Non-SENSEI

LocationRUCS indoor to combustiblesRUCS indoor to non-combustiblesRUS outdoor to combustiblesRUS outdoor to non-combustibles
Top6 in. (152 mm) *2 in. (51 mm) *12 in. (305 mm)2 in. (51 mm)
Back0 in.0 in.0 in.0 in.
Front6 in. (152 mm)6 in. (152 mm)--
Front (panel)--24 in. (610 mm)0 in.
Front (exhaust)--24 in. (610 mm)24 in. (610 mm)
Sides2 in. (51 mm)1/2 in. (13 mm)6 in. (152 mm)1/8 in. (3.2 mm)
Ground/bottom12 in. (305 mm)12 in. (305 mm)12 in. (305 mm)2 in. (51 mm)
Vent0 in.0 in.--
  • 0 in. from vent components and condensate drain line.
  • Service clearance 24 in. in front of the heater; closet installs need 6 in. (152 mm) in front.
  • RUCS models are indoor only and RUS models are outdoor only.

Source: Rinnai KCM Series (RUCS/RUS) Installation and Operation Manual (U328-0700X04(00)), Unit clearances, p.10

RUCS/RUS water quality limits

Water quality · Non-SENSEI

ContaminantMaximum level
Total hardnessUp to 200 mg / L
AluminumUp to 0.2 mg / L
ChloridesUp to 250 mg / L
CopperUp to 1.0 mg / L
Dissolved CO2Up to 15.0 mg / L or PPM
IronUp to 0.3 mg / L
ManganeseUp to 0.05 mg / L
pH6.5 to 8.5
TDSUp to 500 mg / L
ZincUp to 5 mg / L
  • Scale build-up shows as code LC# on a controller (LC on the status monitor without one); flush the heat exchanger.
  • ScaleCutter parts: 103000038 (system), 103000039 (refill).

Source: Rinnai KCM Series (RUCS/RUS) Installation and Operation Manual (U328-0700X04(00)), Water Quality, p.6

Water quality limits - RU/RUR/CU

Water quality · SENSEI

ContaminantMaximum level
Total hardnessUp to 200 mg/L
AluminumUp to 0.2 mg/L
ChloridesUp to 250 mg/L
CopperUp to 1.0 mg/L
Dissolved carbon dioxide (CO2)Up to 15.0 mg/L
IronUp to 0.3 mg/L
ManganeseUp to 0.05 mg/L
pH6.5 to 8.5
TDS (total dissolved solids)Up to 500 mg/L
ZincUp to 5 mg/L
  • Damage from water beyond these levels is not covered by warranty.
  • Hard water needs treatment and more frequent flushing; the Service Soon (SS) reminder can be enabled.

Source: Rinnai Tankless Water Heater (Residential) Installation and Operation Manual (100000467) Table 5 p.19; Rinnai Tankless Water Heater (With Pump) Installation and Operation Manual (100000508) Table 5 p.19; Rinnai Tankless Water Heater (Commercial) Installation and Operation Manual (100000504) Table 5 p.19

Clearances - RU/RUR/CU

Clearances · SENSEI

LocationClearance to combustibles and non-combustibles
Top2 in. (51 mm); 0 in. from vent components
Bottom / ground12 in. (305 mm)
Front0 in.; 24 in. (610 mm) in front for servicing
Back0 in.
Sides (left and right)2 in. (51 mm); add 0.25 in. (6.35 mm) for recess box
Vent (indoor models)0 in.
Front exhaust (outdoor models)24 in. (610 mm)

Source: Rinnai Tankless Water Heater (Residential) Installation and Operation Manual (100000467) Table 6 p.22; Rinnai Tankless Water Heater (With Pump) Installation and Operation Manual (100000508) Table 6 p.22; Rinnai Tankless Water Heater (Commercial) Installation and Operation Manual (100000504) Table 6 p.22

Models covered

C199eC199iCU160eCU160iCU199eCU199iCX160iCX199iCXP160iCXP199iR50LSiR63LSe2R75LSeR75LSiR94LSeR94LSiR98LSeR98LSe-ASMER98LSiR98LSi-ASMERC80eRC80iRC98eRC98iRE140eRE140iRE160eRE160iRE180eRE180iRE199eRE199iREP160eREP160iREP199eREP199iRH180RL75eRL75e(A)RL75iRL75i(A)RL94eRL94iRLX94iRSC160eRSC160iRSC199eRSC199iRU130eRU130iRU160eRU160iRU180eRU180iRU199eRU199iRU80eRU80iRU90eRU98eRU98iRUC80iRUC90iRUC98iRUCS65iRUCS75iRUR160eRUR160iRUR199eRUR199iRUR98eRUR98iRUS65eRUS75eRX130iRX160iRX180iRX199iRXP160iRXP199iV53DeV53eV65eV65iV75eV75iV94XiV94eV94i

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.