Navien · Tankless water heater

E060 Dual venturi abnormal

High severity Navien NPE-2

What the control is telling you

The dual venturi (gas/air valve for staging) is not working correctly.

Applies to: Navien NPE-A2 (built-in recirculation) and NPE-S2 condensing tankless water heaters: NPE-150S2, NPE-180A2/S2, NPE-210A2/S2, NPE-240A2/S2

Likely causes

  • Dual venturi actuator or wiring fault

Test and repair steps

  1. Run Service menu (hold Menu + Back 3 s) > 3. Test Mode > 3. Dual Venturi: it turns on when entered and toggles with Up/Down - listen/watch for movement.
  2. Check the dual venturi connector and wiring.
  3. Reset once with the Back button on the front panel and note whether the code returns.
  4. Fix given phone Navien Technical Support, 1-800-519-8794.

Settings for these units

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Navien NPE-A2/S2 User's Information Manual (20049624A), 5.2 Understanding Error Codes, p.17. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.