Navien · Combi boiler

E439 No DHW flow detected / flow sensor fault

Medium severity Navien NCB-HNavien NFC-H

What the control is telling you

The DHW flow sensor is not reporting correctly (NFC-H: abnormal flow sensor). NFC-H manual lists the reset type as: Alarm.

Applies to: Navien fire-tube combi boilers, NFC-H series (NFC-250/200H, NFC-250/175H) and NCB-H combi boilers (NCB-250/150H, NCB-240/130H, NCB-240/110H, NCB-190/080H, NCB-190/060H)

Likely causes

  • Clogged cold water inlet filter
  • Flow sensor wiring or failure
  • Hot water draw below 0.5 GPM

Test and repair steps

  1. Clean the DHW cold water inlet filter.
  2. Check Status Information > 15. DHW Flow while a tap is open (the boiler needs about 0.5 GPM to start DHW).
  3. Check the flow sensor connector and wiring.
  4. Code keeps returning? Phone Navien Technical Support, 1-800-519-8794.

Settings for these units

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Navien NCB-H Installation & Operation Manual, 11.7 Understanding Error Codes, p.129-130; Navien NFC-H Installation Manual, 11.7 Understanding Error Codes, p.127-128. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.