Midea · Heat pump
PC0L Outdoor unit low-temperature protection
What the control is telling you
Outdoor ambient is below the unit's operating range, so it stops. Operating range: regular models heat down to -5°F (-15°C), High Heat models to -22°F (-30°C); cooling down to 5°F (regular) / -22°F (High Heat).
Applies to: DLCURAH18-60 AAK/ABK single-zone heat pump outdoor units (18K-60K, regular and High Heat)
Likely causes
- Outdoor temperature below operating limit
- T4 sensor reading incorrectly
Test and repair steps
- Compare actual outdoor temperature with the model's operating range.
- If the outdoor temperature is within range, check the T4 ambient sensor.
- Use backup/supplemental heat (terminal W / D) while below range.
Settings for these units
- Outdoor unit minimum clearances · Midea DLCURA ducted single-zone inverter heat pump (outdoor)
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Midea/Carrier DLCURA Installation Instructions (Catalog DLCURA-03SI), Table 11 Outdoor Unit Diagnostic Codes, p.19. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.