Lennox · Heat pump
E601 Low ambient operational lockout
What the control is telling you
Low ambient lockout on the outdoor unit. It won't start at 4 F (-15.6 C) or colder; if already running it keeps going until the call ends or outdoor temp falls to 15 F (-9.4 C). Dealer info. S30/S40 alert code 601; unit control shows E601.
Applies to: Lennox communicating heat pumps incl. variable-capacity inverter units in S30/S40 smart thermostat systems
Likely causes
- Outdoor temperature below the unit's limit
Test and repair steps
- No repair needed; check the outdoor sensor if the reading seems wrong.
- Clears when temperature rises.
Settings for these units
- Outdoor unit clearances · Lennox EL16KP1
- Outdoor unit clearances · Lennox ML14KP1
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Lennox Residential Communicating Systems Alert Code Guide (V2) 100017 (3/2023), Table 2 Alert Codes and Troubleshooting, p.46. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.