Lennox · Air conditioner
E426 Excessive inverter alarms
What the control is telling you
10 inverter faults within 60 consecutive minutes; the control locks out. Inverter flash codes 12 to 14 and 53 do not count. S30/S40 thermostat alert code 426 (shown as E426 on the unit control display).
Applies to: Lennox communicating air conditioners incl. variable-capacity inverter units in S30/S40 smart thermostat systems
Likely causes
- Repeated inverter faults
Test and repair steps
- Check the inverter history for the underlying fault code and fix it.
- Clear by disconnecting power to the outdoor control and restarting.
Settings for these units
- Outdoor unit clearances · Lennox EL16KC1
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Lennox Residential Communicating Systems Alert Code Guide (V2) 100017 (3/2023), Table 2 Alert Codes and Troubleshooting, p.33. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.