Heat & Glo · Gas fireplace

LED Off LED not flashing - no power to module

Medium severity DSI

What the control is telling you

No LED activity on the DSI module means the module is not getting 110/120 VAC or has failed.

Applies to: Older Heat-N-Glo DSI gas fireplaces with RAM 1MC1-01/-05, RAM-1-RS, CFX-DA, Grand-50-C (120 VAC modules); LED applies to RAM 1MC1, CFX-DA and Grand-50-C

Likely causes

  • Breaker off or junction box wiring fault
  • On/Off rocker or wall switch not passing power
  • Failed DSI module

Test and repair steps

  1. Check for 110/120 VAC at the REM receptacle on the junction box. None = check the breaker and the junction box wiring.
  2. With the rocker ON, measure from the black wire on the switch to the On/Off pin (yellow wire) on the module: 110/120 VAC expected.
  3. Measure AC HOT (black) to AC RTN (white) at the module. If 110/120 VAC is there and the LED is still dark, replace the module.
  4. On units with a high-temperature limit switch, check it too (see the ignitor will not spark guide).

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Heat-N-Glo DSI / HSI Troubleshooting Guide (Professional Development), Problem: the ignitor will not spark, p.8, 15, 34, 42. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.