Rinnai boiler error codes

33 codes with causes and test steps.

CodeMeaningSeverity
100Air intake/exhaust blockage or full condensate trapCritical
110Ignition failureHigh
120Flame failure (flame lost during operation)High
140Overheat switch tripped (heat exchanger overheating)Critical
150Venturi control faultHigh
170Venturi blockage / position mismatchHigh
180Gas valve air/fuel adjustment limit reachedHigh
190Electrical grounding / short in DC circuitHigh
210Data transfer errorMedium
220Gas valve position not detected (reed switch)Medium
250Condensate pump switch tripped (accessory)High
303Secondary system thermistor faultMedium
310Freeze protection thermistor faultMedium
353CH supply thermistor faultMedium
363CH return thermistor faultMedium
371Indirect tank thermistor faultMedium
380Exhaust thermistor faultMedium
393Outdoor temperature sensor faultMedium
400Water pressure sensor communication faultMedium
430High or low system water pressureHigh
443Low water cut-off (LWCO) activatedHigh
520Gas solenoid valve circuit – flame after valve closeCritical
540High exhaust (flue gas) temperatureCritical
610Combustion fan motor speed faultHigh
700PC Board faultHigh
710Gas solenoid circuit – valve position mismatchHigh
720Flame rod faultHigh
7630-10V external control input over-voltageMedium
831Indirect tank call running too longMedium
890Freeze condition detectedHigh
999PC Board / software mismatchHigh
FFFMaintenance performed markerLow
SSService Soon reminderLow

Models covered

IP060SIP090SIP120SIP150SIP175SIP199S

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.