Rheem · Furnace

r Lockout indicator

High severity RGPE/RGLE

What the control is telling you

Shown on the seven-segment displays when the IFC is in lockout (defined in the Fig. 45 troubleshooting chart, not in Table 16).

Applies to: RGPE/RGLE 2-stage 80+

Likely causes

  • Repeated ignition failure or other lockout fault

Test and repair steps

  1. Read the fault buffer (power reset shows the last five codes) to find the cause.
  2. Fix the cause.
  3. Shut off main power, wait 30 s and restore, or remove and re-establish the heat call.

Settings for these units

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: RGPE/RGLE: Table 16 p.49 / Table 20; Fig. 45 p.63. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.