Navien · Tankless water heater
E788 Gas type mismatch: DIP switch vs panel setting
What the control is telling you
The gas type on front-panel DIP switch 1 does not match the gas type stored in the panel. Expected right after changing DIP switch 1 during a conversion.
Applies to: Navien NPE-A2 (built-in recirculation) and NPE-S2 condensing tankless water heaters: NPE-150S2, NPE-180A2/S2, NPE-210A2/S2, NPE-240A2/S2
Likely causes
- DIP switch 1 changed (gas conversion)
- Panel gas setting not updated
Test and repair steps
- Confirm the gas supplied and the rating plate.
- Set DIP switch 1 OFF natural gas, ON propane (power off when changing).
- Power on; in the error screen press Back to open Gas Type Check in the Start-Up Wizard and select the gas type.
- On propane, accept the Gas Conversion Kit Required prompt. The error then clears and the unit fires.
- After any conversion, check CO2 or the low-fire offset pressure against the conversion tables.
Settings for these units
- Installation clearances (indoor / outdoor) · Navien NPE-2
- Water quality limits and flushing schedule · Navien NPE-2
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Navien NPE-A2/S2 User's Information Manual (20049624A), 5.2 Understanding Error Codes, p.18; Navien NPE-A2/S2 Installation Manual, 8.1, p.112. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.