Navien · Tankless water heater

E439 Flow sensor abnormal

Medium severity Navien NPE-2

What the control is telling you

The water flow sensor signal is abnormal.

Applies to: Navien NPE-A2 (built-in recirculation) and NPE-S2 condensing tankless water heaters: NPE-150S2, NPE-180A2/S2, NPE-210A2/S2, NPE-240A2/S2

Likely causes

  • Flow sensor or wiring fault
  • Debris at the inlet filter

Test and repair steps

  1. Clean the cold water inlet filter.
  2. Check the flow sensor connector and wiring.
  3. Compare Status Information > 3. Flow Rate with actual flow.
  4. Reset once with the Back button on the front panel and note whether the code returns.
  5. Fix given phone Navien Technical Support, 1-800-519-8794.

Settings for these units

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Navien NPE-A2/S2 User's Information Manual (20049624A), 5.2 Understanding Error Codes, p.17. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.