Lennox · Furnace
E403 LSOM - compressor short cycling
What the control is telling you
Compressor runs less than 3 minutes to satisfy demand (table title says less than 4 minutes). Note: the manual's text for this code is inconsistent; verify on the unit.
Applies to: EL296UHV(X) series furnaces with integrated control 103130-XX only
Likely causes
- Pressure trips
- Thermostat cycling
Test and repair steps
- Check thermostat cycling and placement.
- Check for outdoor pressure trips.
- Clears after 4 normal cycles or power reset.
Settings for these units
- Recommended filter size by cabinet width · EL296UHV
- Recommended filter size by cabinet width · Lennox SL280UHV
- Filter sizes by cabinet width · Lennox SL297NV
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Lennox EL296UHV(X) Unit Information / Service Literature, Table 5 Ignition Control 103130-XX Diagnostic Codes, p.37. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.