Lennox · Furnace

701 Thermostat temperature above limit

High severity

What the control is telling you

Thermostat reads above its fixed 99 F high limit. S30/S40 thermostat alert code 701.

Applies to: Lennox communicating gas furnaces (e.g. SL280UHV/SL280UHNV, EL296UHV) in S30/S40 smart thermostat systems

Likely causes

  • Hot location or heat source near thermostat
  • Sensor fault

Test and repair steps

  1. Cool the thermostat / remove the heat source.
  2. Adjust set point.
  3. Run Reset All in the dealer control center.
  4. Change the HD display or the mag-mount as required.

Settings for these units

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Lennox Residential Communicating Systems Alert Code Guide (V2) 100017 (3/2023), Table 2 Alert Codes and Troubleshooting, p.47. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.