Lennox · Air handler
E420 EIM defrost out of cycle
What the control is telling you
Defrost on the heat pump ran over 20 minutes (non-communicating heat pump paired with a communicating indoor unit). S30/S40 alert code 420; unit control shows E420.
Applies to: Lennox communicating air handlers and EIM-equipped indoor units in S30/S40 smart thermostat systems
Likely causes
- Heat pump defrost control problem
- Low charge or coil sensor issue
Test and repair steps
- Check heat pump defrost operation.
- Clears when the W1 signal is removed.
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Lennox Residential Communicating Systems Alert Code Guide (V2) 100017 (3/2023), Table 2 Alert Codes and Troubleshooting, p.32. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.