Lennox · Air handler
E351 Electric heat stage 1 fault
What the control is telling you
Air handler first-stage electric heat fault: its pilot relay coil was not energized or the contacts stayed open. S30/S40 alert code 351; unit control shows E351.
Applies to: Lennox communicating air handlers and EIM-equipped indoor units in S30/S40 smart thermostat systems
Likely causes
- Failed heat relay/sequencer
- Open heating element or limit
- Wiring fault
Test and repair steps
- Check 24 VAC to the stage relay coil and whether the contacts close.
- Check element continuity and limits for that stage.
- The air handler runs on heat pump first stage for the rest of the call.
- Clears after the fault recovers.
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Lennox Residential Communicating Systems Alert Code Guide (V2) 100017 (3/2023), Table 2 Alert Codes and Troubleshooting, p.27. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.