Lennox · Air conditioner

E601 Low ambient operational lockout

Low severity

What the control is telling you

Low ambient lockout on the outdoor unit. It won't start at 4 F (-15.6 C) or colder; if already running it keeps going until the call ends or outdoor temp falls to 15 F (-9.4 C). Dealer info. S30/S40 alert code 601; unit control shows E601.

Applies to: Lennox communicating air conditioners incl. variable-capacity inverter units in S30/S40 smart thermostat systems

Likely causes

  • Outdoor temperature below the unit's limit

Test and repair steps

  1. No repair needed; check the outdoor sensor if the reading seems wrong.
  2. Clears when temperature rises.

Settings for these units

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Lennox Residential Communicating Systems Alert Code Guide (V2) 100017 (3/2023), Table 2 Alert Codes and Troubleshooting, p.46. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.