Lennox · Air conditioner
E412 Open high pressure switch
What the control is telling you
High side pressure is above the upper limit; the system shuts down (dealer information). S30/S40 thermostat alert code 412 (shown as E412 on the unit control display).
Applies to: Lennox communicating air conditioners incl. variable-capacity inverter units in S30/S40 smart thermostat systems
Likely causes
- Overcharge
- Condenser fan failure or dirty outdoor coil
- Expansion valve problem
- Indoor blower failure (heat pump heating)
- Stuck reversing valve or clogged filter drier
Test and repair steps
- Confirm correct refrigerant charge.
- Check the condenser fan motor, expansion valve, indoor blower, reversing valve and filter drier.
- Clean the outdoor unit.
- Clears when the switch closes or after power reset.
Settings for these units
- Outdoor unit clearances · Lennox EL16KC1
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Lennox Residential Communicating Systems Alert Code Guide (V2) 100017 (3/2023), Table 2 Alert Codes and Troubleshooting, p.30. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.