Lennox · Air conditioner

E402 System pressure trip

Medium severity

What the control is telling you

Compressor overload, or suction or discharge pressure outside its limits. S30/S40 alert code 402; unit control shows E402.

Applies to: Lennox communicating air conditioners incl. variable-capacity inverter units in S30/S40 smart thermostat systems

Likely causes

  • High or low refrigerant charge
  • Dirty coil or failed fan
  • Restriction

Test and repair steps

  1. Check discharge and suction pressures.
  2. Check outdoor coil, fan and indoor airflow.
  3. Clears after four consecutive normal compressor run cycles.

Settings for these units

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Lennox Residential Communicating Systems Alert Code Guide (V2) 100017 (3/2023), Table 2 Alert Codes and Troubleshooting, p.29. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.