FlowMax · Combi boiler

E35 Flame detection fault (false flame)

High severity FlowMax condensing combi (FLOWMAX-90/120)

What the control is telling you

The board is detecting a flame signal when it should not, or the flame circuit is faulty.

Applies to: FLOWMAX-90, FLOWMAX-120

Likely causes

  • Ionization electrode faulty or dirty
  • Ionization electrode lead faulty
  • Control board faulty

Test and repair steps

  1. Turn off power and gas before removing the electrode.
  2. Inspect the ionization electrode; clean it, or replace it if damaged.
  3. Check the ionization lead and replace it if faulty.
  4. If the code remains, replace the control board.
  5. Warning: Gas work only by a qualified gas technician; leak-test all gas connections after any repair.

Settings for these units

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: FlowMax FLOWMAX-120 Instruction Manual, 6.10 Troubleshooting table, p.66; FlowMax FLOWMAX-120 Instruction Manual, 6.11 Diagnostics error code list, p.67; FlowMax FLOWMAX-90 User Manual, Diagnostics - Error codes, p.8-9. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.