Carrier · Heat pump

48 Lost inverter communication - lockout

High severity Carrier Infinity 18VS 25VNA8

What the control is telling you

Amber STATUS light flashes 48. Communication between AOC and inverter (MOC) keeps failing (elevated from code 33). The system retries starting on its own. Type: System malfunction; reset: Automatic retries.

Applies to: Carrier Infinity 18VS variable speed heat pump 25VNA8 (AOC control + inverter)

Likely causes

  • Loose or disconnected harness between AOC (PL20) and inverter
  • Electrical noise / radio interference
  • Damaged inverter

Test and repair steps

  1. Check and reseat the harness between the AOC board and the inverter.
  2. Look for sources of electrical noise near the wiring.
  3. If the harness is good and the fault returns, replace the inverter drive.

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Carrier 25VNA8 / 24VNA9 Service Manual, Table 6 Fault Code Actions, p.19. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.