57 Suction pressure transducer fault
What the control is telling you
Amber STATUS light flashes 57. The suction pressure transducer (SPT) signal is missing or out of range. Type: Fault; reset: None (fix the transducer).
Applies to: Carrier Infinity 19VS variable speed air conditioner 24VNA9 (AOC control + inverter)
Likely causes
- Transducer plug not connected to the AOC board
- Broken or loose harness wire
- Transducer damaged by an electrical short
- Transducer damaged by heat during brazing
Test and repair steps
- Check the plug and harness.
- Compare the transducer reading with a gauge at the service valve (transducer chart in the manual).
- Correct any electrical short, then replace the transducer if readings do not match.
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Carrier 25VNA8 / 24VNA9 Service Manual, Table 6 Fault Code Actions, p.20. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.